Applications: Temperature limit of heaters, instant water heaters, saunas steam generators, industrial heaters
Housing dimensions: diameter 45mm, height 20mm (28mm with terminals),
Body material: high temperature PPS
Temperature sensing element: Bimetal disc
Terminals: 6.35 x 0.8mm quick connect
Set point temperature range: +20 to +180°C (Factory fixed setting only)
Mounting: surface mounting fixed bracket, 2 holes 4.4 x 6.4mm, 60 mm distance
Rating: 3 x 16A 250VAC, 3 x 10A 400VAC, resistive (10000 cycles) 3 x 25A 250VAC, 3 x 16A 400VAC (300 cycles)
Contact: 3 snap action contacts, double break, open on temperature rise.
Max ambient temperature: 180°C
Approvals: comply with EN 60730-1 and EN 60730-2 standards (CE mark)
Main references
References |
Operating Temperature (°C/°F) |
Tolerance (°C/°F) |
References |
Operating Temperature (°C/°F) |
Tolerance (°C/°F) |
4C504T070RMEM60D |
70°C/158°F |
±4°C/±39.2°F |
4C504T105RMEM60D |
105°C/221°F |
±6°C/±42.8°F |
4C504T075RMEM60D |
75°C/167°F |
±4°C/±39.2°F |
4C504T110RMEM60D |
110°C/230°F |
±6°C/±42.8°F |
4C504T080RMEM60D |
80°C/176°F |
±5°C/±41°F |
4C504T120RMEM60D |
120°C/248°F |
±6°C/±42.8°F |
4C504T085RMEM60D |
85°C/185°F |
±5°C/±41°F |
4C504T130RMEM60D |
130°C/266°F |
±6°C/±42.8°F |
4C504T090RMEM60D |
90°C/194°F |
±5°C/±41°F |
4C504T140RMEM60D |
140°F/284°F |
±7°C/±44.6°F |
4C504T095RMEM60D |
95°C/203°F |
±5°C/±41°F |
4C504T150RMGM60D |
150°C/302°F |
±7°C/±44.6°F |
4C504T100RMEM60D |
100°C/212°C |
±5°C/±41°F |
4C504T160RMEM60D |
160°C/320°F |
±7°C/±44.6°F |
|
|