These enclosures include a stainless-steel removable locking device for the power cable and an internal and external grounding terminal.
Some models also include a thick insulating silicone foam pad to thermally insulate the thermostat body from the temperature of the heater.
The models for bulb and capillary thermostat have a lateral outlet for the capillary.
The flexibility of the silicone makes it possible to use cables with a diameter slightly greater (up to 15%) than that of the passage opening.
1: Round wires FEP insulation, 300V, dimensions USA;
2: Round wires FEP insulation, 300V, European dimensions;
3: Flat cable PVC insulation, 300V, European dimensions;
4: Round cables 2 conductors PVC insulation, 300V, European dimensions;
5: Round cables 3 conductors PVC insulation, 300V, European dimensions: 6: Round cables 3 conductors rubber insulation 300V, European and USA dimensions. 7: Round cables 5 conductors rubber insulation 300V, European and USA dimensions.